A matrix inversion technique is derived to calculate local ion temperature from line-integrated measurements of an extended emission source in an axisymmetric plasma which exactly corrects for both toroidal velocity and radial velocity components. Local emissivity and toroidal velocity can be directly recovered from line-integrated spectroscopic measurements, but an independent measurement of the radial velocity is necessary to complete the temperature inversion. The extension of this technique to handle the radial velocity is relevant for magnetic reconnection and merging compression devices where temperature inversion from spectroscopic measurements is desired. A simulation demonstrates the effects of radial velocity on the determination of ion temperature.
Rafiq T; Kaye S; Guttenfelder W; Weiland J; Schuster E; Anderson J; Luo L;
Abstract:
Microtearing mode (MTM) real frequency, growth rate, magnetic fluctuation amplitude and resulting electron thermal transport are studied in systematic NSTX scans of relevant plasma parameters. The dependency of the MTM real frequency and growth rate on plasma parameters, suitable for low and high collision NSTX discharges, is obtained by using the reduced MTM transport model [T. Rafiq, et al., Phys. Plasmas 23, 062507 (2016)]. The plasma parameter dependencies are compared and found to be consistent with the results obtained from MTM using the Gyrokinetic GYRO code. The scaling trend of collision frequency and plasma beta is found to be consistent with the global energy confinement trend observed in the NSTX experiment. The strength of the magnetic fluctuation is found to be consistent with the gyrokinetic estimate.In earlier studies, it was found that the version of the Multi-Mode (MM) anomalous transport model, which did not contain the effect of MTMs, provided an appropriate description of the electron temperature profiles in standard tokamak discharges and not in spherical tokamaks. When the MM model, which involves transport associated with MTMs, is incorporated in the TRANSP code and is used in the study of electron thermal transport in NSTX discharges, it is observed that the agreement with the experimental electron temperature profile is substantially improved.
Magnetic reconnection in partially ionized plasmas is a ubiquitous and important phenomena in both laboratory and astrophysical systems. Here, simulations of partially ionized magnetic reconnection with well-matched initial conditions are performed using both multi-fluid and fully-kinetic approaches. Despite similar initial conditions, the time-dependent evolution differs between the two models. In multi-fluid models, the reconnection rate locally obeys either a decoupled Sweet-Parker scaling, where neutrals are unimportant, or a fully coupled Sweet-Parker scaling, where neutrals and ions are strongly coupled, depending on the resistivity. In contrast, kinetic models show a faster reconnection rate that is proportional to the fully-coupled, bulk Alfv\'en speed, $v_A^\star$. These differences are interpreted as the result of operating in different collisional regimes. Multi-fluid simulations are found to maintain $\nu_{ni}L/v_A^\star \gtrsim 1$, where $\nu_{ni}$ is the neutral-ion collision frequency and $L$ is the time-dependent current sheet half-length. This strongly couples neutrals to the reconnection outflow, while kinetic simulations evolve to allow $\nu_{ni}L/v_A^\star < 1$, decoupling neutrals from the reconnection outflow. Differences in the way reconnection is triggered may explain these discrepancies.
Choi, W.; Poli, F. M.; Li, M. H.; Baek, S. G.; Gorenlenkova, M.; Ding, B. J.; Gong, X. Z.; Chan, A.; Duan, Y. M.; Hu, J. H.; Lian, H.; Lin, S. Y.; Liu, H. Q.; Qian, J. P.; Wallace, G.; Wang, Y. M.; Zang, Q.; Zhao, H. L.
Abstract:
Synergistic effects between two frequencies of lower hybrid (LH) waves—operating at 2.45 and 4.6 GHz—were observed in experiment on EAST for the first time. At low density (n_e,lin ≈ 2.0 × 10^19m^−3), simultaneous injection of a 65/35 mix of 2.45 GHz/4.6 GHz power achieved an LHCD efficiency that was 25% higher than what should be expected from the linear combination of the two sources. The experiment was interpreted with time-dependent simulations, using the equilibrium and transport solver TRANSP, coupled with the ray-tracing code GENRAY and the Fokker-Planck solver CQL3D. For each discharge, profiles of current and hard x-ray from simulation and measurement agree within uncertainties. An examination of the electron distribution function indicates that the LH synergy is supported by the increased width of the LH resonance plateau in the simultaneous injection case compared to independent injection.
A new model for prediction of electron density and pressure profile shapes on NSTX and NSTX-U has been developed using neural networks. The model has been trained and tested on measured profiles from experimental discharges during the first operational campaign of NSTX-U. By projecting profiles onto empirically derived basis functions, the model is able to efficiently and accurately reproduce profile shapes. In order to project the performance of the model to upcoming NSTX-U operations, a large database of profiles from the operation of NSTX is used to test performance as a function of available data. The rapid execution time of the model is well suited to the planned applications, including optimization during scenario development activities, and real-time plasma control. A potential application of the model to real-time profile estimation is demonstrated.