Here we publish the data used in paper "Junming Huang, Gavin Cook, and Yu Xie, Large-scale Quantitative Evidence of Media Impact on Public Opinion toward China". This dataset include estimated sentiments on The New York Times on China in eight topics from 1970 to 2019, and a time series of public attitude aggregated from surveys on China.
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; Fisher, A. E.
Abstract:
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of
applications in a variety of different industries. However, calibrating these flowmeters can
be challenging, time-consuming, and expensive. In this paper, simple calibration procedures
for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for
expensive equipment, numerical modeling, redundant flowmeters, and system down-time.
The calibration processes are explained in a step-by-step manner and compared to experimental results.
This setup mimics ice lying above the drainage system. In the experiment, a fluid-filled blister is generated via liquid injection into the interface between a transparent elastic layer and a porous substrate. After injection of liquid, the fluid permeates from the blister through the porous substrate, the blister volume V(t) relaxes exponentially with time. Our lab experiments show that varying the permeability of the porous substrate k significantly impacts the relaxation timescale in the experiments.
In this paper, hydraulic jump control using electromagnetic force in a liquid metal flow is presented. The control methods used give insight into the hydraulic jump behavior in the presence of magnetic fields and electrical currents. Flowing liquid metals is a proposed solution to heat flux challenges posed in fusion reactors, specifically the tokamak. Unfortunately, thin, fast-flowing liquid metal divertor concepts for fusion reactors are susceptible to hydraulic jumps that drastically reduce the liquid metal flow speed, leading to potential problems such as excessive evaporation, unsteady power removal, and possible plasma disruption. Highly electrically conductive flows within the magnetic fields do not exhibit traditional hydraulic jump behavior. There is very little research investigating the use of externally injected electrical currents and magnetic fields to control liquid metal hydraulic jumps. By using externally injected electrical currents and a magnetic field, a Lorentz force (also referred to as j × B force) may be generated to control the liquid metal jump behavior. In this work, a free-surface liquid metal—GaInSn eutectic or “galinstan”—flow through an electrically insulating rectangular duct was investigated. It was shown that applying a Lorentz force has a repeatable and predictable impact on the hydraulic jump, which can be used for liquid metal control within next-generation fusion reactors.
Pereira, Talmo D.; Aldarondo, Diego E.; Willmore, Lindsay; Kislin, Mikhail; Wang, Samuel S.-H.; Murthy, Mala; Shaevitz, Joshua W.
Abstract:
Recent work quantifying postural dynamics has attempted to define the repertoire of behaviors performed by an animal. However, a major drawback to these techniques has been their reliance on dimensionality reduction of images which destroys information about which parts of the body are used in each behavior. To address this issue, we introduce a deep learning-based method for pose estimation, LEAP (LEAP Estimates Animal Pose). LEAP automatically predicts the positions of animal body parts using a deep convolutional neural network with as little as 10 frames of labeled data for training. This framework consists of a graphical interface for interactive labeling of body parts and software for training the network and fast prediction on new data (1 hr to train, 185 Hz predictions). We validate LEAP using videos of freely behaving fruit flies (Drosophila melanogaster) and track 32 distinct points on the body to fully describe the pose of the head, body, wings, and legs with an error rate of <3% of the animal's body length. We recapitulate a number of reported findings on insect gait dynamics and show LEAP's applicability as the first step in unsupervised behavioral classification. Finally, we extend the method to more challenging imaging situations (pairs of flies moving on a mesh-like background) and movies from freely moving mice (Mus musculus) where we track the full conformation of the head, body, and limbs.
This paper examines a method for real-time control of non-inductively sustained scenarios in NSTX-U by using TRANSP,
a time-dependent integrated modeling code for prediction and interpretive analysis of tokamak experimental data, as a
simulator. The actuators considered for control in this work are the six neutral beam sources and the plasma boundary
shape. To understand the response of the plasma current, stored energy, and central safety factor to these actuators
and to enable systematic design of control algorithms, simulations were run in which the actuators were modulated and
a linearized dynamic response model was generated. A multi-variable model-based control scheme that accounts for the
coupling and slow dynamics of the system while mitigating the effect of actuator limitations was designed and
simulated. Simulations show that modest changes in the outer gap and heating power can improve the response time of
the system, reject perturbations, and track target values of the controlled values.
Kim, Donghoon; Tracy, Sally J.; Smith, Raymond F.; Gleason, Arianna E.; Bolme, Cindy A.; Prakapenka, Vitali B.; Appel, Karen; Speziable, Sergio; Wicks, June K.; Berryman, Eleanor J.; Han, Sirus K.; Schoelmerich, Markus O.; Lee, Hae Ja; Nagler, Bob; Cunningham, Eric F.; Akin, Minta C.; Asimow, Paul D.; Eggert, Jon H.; Duffy, Thomas S.
Abstract:
The behavior of forsterite, Mg2SiO4, under dynamic compression is of fundamental importance for understanding its phase transformations and high-pressure behavior. Here, we have carried out an in situ X-ray diffraction study of laser-shocked poly- and single-crystal forsterite (a-, b-, and c- orientations) from 19 to 122 GPa using the Matter in Extreme Conditions end-station of the Linac Coherent Light Source. Under laser-based shock loading, forsterite does not transform to the high-pressure equilibrium assemblage of MgSiO3 bridgmanite and MgO periclase, as was suggested previously. Instead, we observe forsterite and forsterite III, a metastable polymorph of Mg2SiO4, coexisting in a mixed-phase region from 33 to 75 GPa for both polycrystalline and single-crystal samples. Densities inferred from X-ray diffraction data are consistent with earlier gas-gun shock data. At higher stress, the behavior observed is sample-dependent. Polycrystalline samples undergo amorphization above 79 GPa. For [010]- and [001]-oriented crystals, a mixture of crystalline and amorphous material is observed to 108 GPa, whereas the [100]-oriented crystal adopts an unknown crystal structure at 122 GPa. The Q values of the first two sharp diffraction peaks of amorphous Mg2SiO4 show a similar trend with compression as those observed for MgSiO3 glass in both recent static and laser-compression experiments. Upon release to ambient pressure, all samples retain or revert to forsterite with evidence for amorphous material also present in some cases. This study demonstrates the utility of femtosecond free-electron laser X-ray sources for probing the time evolution of high-pressure silicates through the nanosecond-scale events of shock compression and release.
A subset of the Fermi-LAT public data for use with NPTFit:
https://github.com/bsafdi/NPTFit
The data here is for use with the Jupyter example notebooks provided with the
main code. Details of the files provided are given below. All files are provided
as numpy arrays binned as nside=128 HEALPix maps.
For the full public data, see:
http://fermi.gsfc.nasa.gov/ssc/data/access/
In this publication we provide the LAMMPS example files to reproduce simulations for the manuscript "A Deep Potential model for liquid-vapor equilibrium and cavitation rates of water"
The data provided in this DataSpace consists of sample training data to be used for Fluorescence Reconstruction Microscopy (FRM) testing. We provide a subset of the keratinocyte (10x magnification) dataset used in our paper, in which interested parties may find more complete information about our data collection methods. Matched pairs of phase contrast and fluorescent images are given. The nuclei were stained using Hoechst 33342 and imaged using a standard DAPI filter set.
The data provided in this DataSpace consists of sample training data to be used for Fluorescence Reconstruction Microscopy (FRM) testing. We provide a subset of the MDCK (20x magnification) dataset used in our paper, in which interested parties may find more complete information about our data collection methods. Matched pairs of DIC and fluorescent images are given. The cells stably expressed E-cadherin:RFP which enabled imaging of junctional fluorescence, while the nuclei were stained using Hoechst 33342 and imaged using a standard DAPI filter set.
We provide all the test data and corresponding predictions for our paper, “Practical Fluorescence Reconstruction Microscopy for High-Content Imaging”. Please refer to the Methods section in this paper for experimental details. For each experimental condition, we provide the input transmitted-light images (either phase contrast or DIC), the ground truth fluorescence images, and the output predicted fluorescence images which should reconstruct the ground truth fluorescence images.
Fractures in geological formations may enable migration of environmentally relevant fluids, as in leakage of CO2 through caprocks in geologic carbon sequestration. We investigated geochemically induced alterations of fracture geometry in Indiana Limestone specimens. Experiments were the first of their kind, with periodic high-resolution imaging using X-ray computed tomography (xCT) scanning while maintaining high pore pressure (100 bar). We studied two CO2-acidified brines having the same pH (3.3) and comparable thermodynamic
disequilibrium but different equilibrated pressures of CO2 (PCO2 values of 12 and 77 bar). High-PCO2 brine has a faster calcite dissolution kinetic rate because of the accelerating effect of carbonic acid. Contrary to expectations, dissolution extents were comparable in the two experiments. However, progressive xCT
images revealed extensive channelization for high PCO2, explained by strong positive feedback between ongoing flow and reaction. The pronounced channel increasingly directed flow to a small region of the fracture, which explains why the overall dissolution was lower than expected. Despite this, flow simulations revealed large increases in permeability in the high-PCO2 experiment. This study shows that the permeability evolution of dissolving fractures will be larger for faster-reacting fluids. The overall mechanism is not because more rock dissolves, as would be commonly assumed, but because of accelerated fracture channelization.
Bertelli, N; Valeo, E.J.; Green, D.L.; Gorelenkova, M.; Phillips, C.K.; Podesta, M.; Lee, J.P.; Wright, J.C.; Jaeger, E.
Abstract:
At the power levels required for significant heating and current drive
in magnetically-confined toroidal plasma, modification of the particle distribution
function from a Maxwellian shape is likely [T. H. Stix, Nucl. Fusion, 15 737
(1975)], with consequent changes in wave propagation and in the location and
amount of absorption. In order to study these effects computationally, both the
finite-Larmor-radius and the high-harmonic fast wave (HHFW), versions of the
full-wave, hot-plasma toroidal simulation code TORIC [M. Brambilla, Plasma Phys.
Control. Fusion 41, 1 (1999) and M. Brambilla, Plasma Phys. Control. Fusion
44, 2423 (2002)], have been extended to allow the prescription of arbitrary velocity
distributions of the form f(v||, v_perp, psi , theta). For hydrogen (H) minority heating of a
deuterium (D) plasma with anisotropic Maxwellian H distributions, the fractional
H absorption varies significantly with changes in parallel temperature but is
essentially independent of perpendicular temperature. On the other hand, for
HHFW regime with anisotropic Maxwellian fast ion distribution, the fractional
beam ion absorption varies mainly with changes in the perpendicular temperature.
The evaluation of the wave-field and power absorption, through the full wave
solver, with the ion distribution function provided by either aMonte-Carlo particle
and Fokker-Planck codes is also examined for Alcator C-Mod and NSTX plasmas.
Non-Maxwellian effects generally tends to increase the absorption with respect to
the equivalent Maxwellian distribution.
Petsev, Nikolai D.; Nikoubashman, Arash; Latinwo, Folarin
Abstract:
Source code for our genetic algorithm optimization investigation of conglomerate and racemic chiral crystals. In this work, we address challenges in determining the stable structures formed by chiral molecules by applying the framework of genetic algorithms to predict the ground state crystal lattices formed by a chiral tetramer model. Using this code, we explore the relative stability and structures of the model’s conglomerate and racemic crystals, and extract a structural phase diagram for the stable Bravais crystal types in the zero-temperature limit.
Sharma, A. Y.; Cole, M. D. J.; Görler, T.; Chen, Y.; Hatch, D. R.; Guttenfelder, W.; Hager, R.; Sturdevant, B. J.; Ku, S.; Mishchenko, A.; Chang, C. S.
The materials include codes and example input / output files for Monte Carlo simulations of lattice chains in the grand canonical ensemble, for determining phase behavior, critical points, and formation of aggregates.
Dielectric tensor for crystalline graphite from X-ray to microwave frequencies, as discussed in the paper "Graphite Revisited" (Draine 2016, Astrophysical Journal, in press). Cross sections for absorption and scattering by graphite spheres and spheroids are also tabulated, as well as Planck-averaged cross sections for absorption and scattering of radiation with a Planck spectrum.
This dataset is affiliated with the publication https://doi.org/10.1007/s00348-022-03455-0. All of the data provided is necessary to reproduce the results with the aforementioned publication. The data in this repository is for the wake of a wind turbine at high Reynolds numbers. The data is mainly used for reproducing the statistics (deficit and variance profiles) and the phase averaged results.
Kaita, R.; Lucia, M.; Allain, J. P.; Bedoya, F.; Capece, A.; Jaworski, M.; Koel, B. E.; Majeski, R.; Roszell, J.; Schmitt, J.; Scotti, F.; Skinner, C. H.; Soukhanovskii, V.
Abstract:
The application of lithium to plasma-facing components (PFCs) has long been used as a technique for wall conditioning in magnetic confinement devices to improve plasma performance. Determining the characteristics of PFCs at the time of exposure to the plasma, however, is difficult because they can only be analyzed after venting the vacuum vessel and removing them at the end of an operational period. The Materials Analysis and Particle Probe (MAPP) addresses this problem by enabling PFC samples to be exposed to plasmas, and then withdrawn into an analysis chamber without breaking vacuum. The MAPP system was used to introduce samples that matched the metallic PFCs of the Lithium Tokamak Experiment (LTX). Lithium that was subsequently evaporated onto the walls also covered the MAPP samples, which were then subject to LTX discharges. In vacuo extraction and analysis of the samples indicated that lithium oxide formed on the PFCs, but improved plasma performance persisted in LTX. The reduced recycling this suggests is consistent with separate surface science experiments that demonstrated deuterium retention in the presence of lithium oxide films. Since oxygen decreases the thermal stability of the deuterium in the film, the release of deuterium was observed below the lithium deuteride dissociation temperature. This may explain what occurred when lithium was applied to the surface of the NSTX Liquid Lithium Divertor (LLD). The LLD had segments with individual heaters, and the deuterium-alpha emission was clearly lower in the cooler regions. The plan for NSTX-U is to replace the graphite tiles with high-Z PFCs, and apply lithium to their surfaces with lithium evaporation. Experiments with lithium coatings on such PFCs suggest that deuterium could still be retained if lithium compounds form, but limiting their surface temperatures may be necessary.